| Model |
RD6006 |
RD6006-W |
RD6012 |
RD6012-W |
| Input voltage range |
6-70.00V |
| Output voltage range |
0-60.00V |
| Output current range |
0-6.000A |
0-12.00A |
| Output power range |
0-360W |
0-720W |
| Input voltage measurement resolution |
0.01V |
| Output voltage setting measurement resolution |
0.01V |
| Output current setting measurement resolution |
0.001A |
0.01A |
| Battery voltage measurement resolution |
0.01V |
| Input voltage measurement accuracy |
±(1%+5 digits) |
| Output voltage accuracy between setting and measurement |
±(0.3%+3 digits) |
| Output current accuracy between setting and measurement |
±(0.5%+5 digits) |
| Battery voltage measurement accuracy |
±(0.5%+3 digits) |
| Automatic cut off current value when charging |
10mA |
100mA |
| Output ripple typical |
100mV VPP |
250mV VPP@6A |
| Working temperature range |
-10?~40? |
| External sensor Temperature detection range: |
-10?~100?/0?~200? |
| External sensor Temperature detection accuracy |
±3?/±6? |
| Constant voltage mode response time |
2ms?0.1A-5A Load? |
2ms?0.1A-5A Load? |
| Constant voltage mode load?regulation |
±(0.1%+2 digits) |
| Constant current mode load?regulation |
±(0.1%+3 digits) |
| Capacity measurement range |
0-9999.99Ah |
| Energy measurement range |
0-9999.99Wh |
| Capacity and energy statistical error |
±2? |
| Buck working mode |
Voltage drop >1V and >10% |
| Cooling fan start condition |
Output voltage >40V
or Output current >4A
or System temperature >45? |
Output current>8A
or System temperature>45? |
| Cooling fan shut down condition when working |
Output voltage <40V
and Output current <3.9A
and System temperature<45? |
Output current <7.9A
and System temperature <45? |
| Over temperature protection |
System temperature >80? |
| Screen brightness setting |
0-5(6 level in total) |
| Screen |
2.4 inch color HD display |
| Weight(with package) |
About 607g |
About 642g |
| Product dimension |
167*81*65mm |
| Support USB communication |
YES |
| Support WiFi communication |
No |
yes |
No |
yes |